Guides · Contract and certification
What strength tests must a hotel chair pass?
A specification asks for a “contract” chair and a supplier sends a test report. Here is which standard applies today to non-domestic seating and tables, after the change of 11 September 2025, what that standard does not cover, and how a piece drawn for one hotel is tested.
In short. The tests that say whether a chair will survive a hotel are not the fire ones: they are mechanical tests, run on one specimen that a laboratory takes to its limit. For non-domestic seating the reference standard has just changed — UNI EN 16139:2013 was withdrawn on 11 September 2025 and replaced by UNI EN 16139:2025 — and for tables UNI EN 15372:2024 applies. The part that settles arguments, though, is a different one: what those standards do not cover.
Which tests are we talking about when we say "contract chair"?
Mechanical ones: safety, strength and durability of the structure. They are a different family of documents from the fire file, which in Italy runs through Class 1 IM type approval and UNI 9175 (when Class 1 IM is required). A piece can have one and not the other, and in a hotel project the two files are asked for at two different moments.
The most frequent confusion is another: the client receives the Martindale report for the fabric and believes he has the test for the chair. Martindale measures abrasion of the covering (how many rubs a hotel needs); the frame, the legs, the joints and the backrest have nothing to do with it. They are two tests on two different standards, and a supply needs both.
Which standard applies today to non-domestic seating?
In the official UNI catalogue, today, it is UNI EN 16139:2025 — "Furniture - Safety, strength and durability - Requirements and test methods for non-domestic seating" — in force since 11 September 2025. On the same day UNI EN 16139:2013 was withdrawn: its title stopped at the requirements and left the test methods to a separate standard.
That separate standard still exists and is listed as current: UNI EN 1728:2012, "Furniture - Seating - Test methods for the determination of strength and durability", which sets out the methods for testing the structure of any kind of seating, regardless of use, materials, design or manufacturing process.
For tables the standard is UNI EN 15372:2024, "Furniture - Strength, durability and safety - Requirements for non-domestic tables", which on 25 January 2024 replaced the 2017 edition and covers all types of non-domestic table, including those with glass among their construction features.
For non-domestic storage furniture — wardrobes, drawer units, counters — the family of standards is different again, and the requirement that decides is stability (does the bedroom wardrobe have to be fixed to the wall?).
Why this matters in a tender: a specification rewritten from a two-year-old document cites the old edition, and a supplier in good faith hands over a report against a withdrawn standard. It will not sink a supply, but it is the first line to update when a specification is reused (how to write the specification).
Who is the test calibrated for? There is a weight limit
Yes, and it is in the scope: the standard covers non-domestic seating intended for use by adults weighing no more than 110 kg, including office visitors' chairs. Above that figure there is no prohibition: there is the absence of a test. Where the issue is real — a busy breakfast room, a waiting area, a bar counter — the question to put to the supplier is not whether the chair "is contract", but whether the structure has been tested at more severe values, and under which document.
What the standard does not cover
This is the most useful list on the page, and it is not an opinion: it is written in the scope of the standard itself. UNI EN 16139:2025 does not apply to bar stools, office chairs, chairs for educational institutions, outdoor seating, linked seat combinations or industrial work chairs: other European standards exist for those.
And within its own scope, it does not include requirements for:
- durability of covering materials;
- castors;
- reclining and tilting mechanisms;
- seat height adjustment mechanisms;
- resistance to ageing and deterioration;
- resistance to flammability;
- electrical safety.
In practice: a compliant chair may have untested castors, a fabric that wears out in one season and no fire document at all, and still be perfectly compliant. That is not a flaw in the standard, it is its perimeter — and it is why the file for a hotel supply holds several documents and not one (which documents to ask for, and what happens to the accessories).
And a bespoke piece? The test destroys the specimen
Here the difference between a catalogue model and a drawing made for one hotel becomes concrete. Strength and durability tests are run on one specimen, with loads and repeated cycles, and that specimen leaves the laboratory unusable. For a production model it is one of many; for forty chairs drawn for a single lobby, it is a piece of the order, and it belongs in the quotation and in the programme.
Three consequences follow, all decided before and not after:
- the prototype is built ahead of the production run, and the mock-up room is the natural moment to stand it up (what the mock-up room is for);
- a variant decided after the test — another leg, another joint, another frame section — is a different piece from the one tested: the same logic as the fire file (test report or type approval);
- laboratory time sits inside the supply programme (FF&E lead times) and is not recovered by squeezing production.
The lines to put in the order
- the standard and the edition written out in full: seating UNI EN 16139:2025, tables UNI EN 15372:2024;
- which piece was tested: model, drawing, date, laboratory;
- what stays outside the test and which document covers it — covering, castors, mechanisms, reaction to fire;
- who supplies and who pays for the specimen to be tested, if the piece is bespoke;
- what happens if, after the test, the design changes a structural detail;
- who receives the documents and when (the handover report).
How we work
We design and manufacture in house, with the wood, marble, metal and upholstery work in our own plant. On a bespoke piece that changes two things: the prototype is built ahead of the production run, and when the design changes a detail we can say at once whether the piece is still the one that was tested or has become a new piece. In a hotel project the most valuable thing is time: pieces made to standard, certified and delivered on programme mean a fast opening, and a client who starts invoicing.
Frequently asked questions
Does a "contract" chair necessarily have a mechanical test report?
No. "Contract" is neither a class nor a certification: it is a figure of speech. The document that counts is a laboratory test report against the standard and the edition in force, referred to a model identified by drawing and date.
Is the Martindale report for the fabric enough for a hotel chair?
No: it measures abrasion of the covering, not the strength of the structure. They are two tests on two different standards, and a supply should ask for both.
Is it a mistake to cite UNI EN 16139:2013 in a specification?
It is out of date: that edition was withdrawn on 11 September 2025 and replaced by UNI EN 16139:2025. Better to write the edition in force, or to require conformity to the edition current at the date of supply.
Talk to us The contract division All guides
The standards cited and their status are verified in the official UNI catalogue at the date of this page; they remain general guidance, and the requirement that applies is the one in the specification and in the approved design.