Guides · Contract and certification

Is the desk chair in a hotel room an office chair?

In a hotel bedroom the chair at the desk is often a swivel chair, on castors, with seat height adjustment. Most specifications put it on the same line as every other chair in the supply: here is why it sits in a different family of standards, which one, and what to ask for.

In short. The non-domestic seating standard says, in its own scope, that it does not apply to office work chairs. A swivel chair on castors with seat height adjustment is an office work chair even when it stands in a hotel bedroom, and the family that covers it is a different one: UNI EN 1335. They are two separate lines in a specification, and a test report against the wrong standard does not describe the piece.

Why this is not a quibble

A specification asks for “seating in conformity with UNI EN 16139” for every seat in the supply, and the schedule lists the tub chairs in the lobby, the chairs in the breakfast room, the stools at the counter and the swivel chair at the bedroom desk. For the first three the request is right. For the last one it is not: that piece falls outside the scope of that standard.

Whoever receives the schedule has three routes: hand over a document that does not apply, ask for a formal variation to the specification, or flag it early and have the line corrected. The last one costs five minutes; the other two cost time at handover, which is the worst moment to discover something like this (how a specification clause is written).

What the scope says, word for word

In the official UNI catalogue, UNI EN 16139:2025 — “Furniture - Safety, strength and durability - Requirements and test methods for non-domestic seating”, in force since 11 September 2025 — covers non-domestic seating intended to be used by adults with a weight of not more than 110 kg, “including office visitor chairs”. The next line is the one that decides: the standard “does not apply to ranked seating, office work chairs, chairs for educational institutions, outdoor seating and to links for linked seating”, nor to work chairs for industrial use.

It is worth reading twice: office visitor chairs are in, office work chairs are out. The difference is not the room, it is the piece. A fixed tub chair in front of a desk is a visitor chair; a swivel chair, on castors, with seat height adjustment, is an office work chair — and standing in a hotel bedroom rather than in an office does not change it.

So which standard covers it?

The UNI EN 1335 family, “Office furniture - Office work chair”. In the catalogue, today, two parts are listed as in force:

  • UNI EN 1335-1:2022, “Part 1: Dimensions - Determination of dimensions”, in force since 15 December 2022, which specifies the dimensions of four types of office work chair and the test methods for determining them;
  • UNI EN 1335-2:2018, “Part 2: Safety requirements”, in force since 6 December 2018, which specifies safety, strength and durability requirements for office work chairs.

One thing to know, so as not to ask for a document that cannot be issued: Part 3, the test methods, is no longer a standard of its own. UNI EN 1335-3:2009 was withdrawn on 6 December 2018, and UNI EN 1335-2:2018 replaces both Part 2 and Part 3 of the previous edition. A specification that says “UNI EN 1335-1/2/3” is asking, for one third of it, for a standard withdrawn seven years ago.

Two notes from the scope of Part 2 that earn their keep on a project. The first: the requirements are based upon use for eight hours a day by persons weighing up to 110 kg. At a hotel bedroom desk that chair works a great deal less than that, and the same test becomes margin rather than a limit. The second: the standard does not apply to other seating in the office area, for which other European Standards exist — so the tub chair, the bench and the stool in the same room stay on their own.

“Ranked seating” is not bar stools

That exclusion is worth a stop, because it is routinely misread as covering stools, and the misreading takes the right document out of the supply. Ranked seating is covered by UNI EN 12727:2017, “Furniture - Ranked seating - Requirements for safety, strength and durability”, in force since 19 January 2017, and its scope speaks of seating “permanently fastened to the floor and/or wall, whether in bench or individual seat form”. The same standard says it does not apply to linked seating that is not fastened to the floor or walls.

These are the rows in a conference hall or an auditorium, bolted down. A counter stool, which gets moved, is not ranked seating: it remains non-domestic seating, and for it UNI EN 16139:2025 is the right standard. If a project has both the counter with its stools and the meeting room with rows fixed to the floor, two different standards run across the same supply.

Castors, gas lift, tilt mechanism: what covers them

Here the two families behave differently, and the difference can be read in their respective scopes.

UNI EN 16139:2025 states that it does not include requirements for the durability of upholstery materials, castors, reclining and tilting mechanisms and seat height adjustment mechanisms (the full list is in what strength tests a hotel chair must pass). UNI EN 1335-2:2018, which is the standard for office work chairs — that is, for exactly the pieces that have castors, a column and adjustment — declares no exclusion of that kind in its own scope.

The full text of the standards is behind payment and cannot be read from the catalogue: what can be verified at source is the perimeter, not the individual tests. The consequence on a project is practical, and it is enough to ask for it in writing: the test report has to say against which standard, which edition and which clauses it was issued. A report that names the standard but not the clauses applied cannot be compared with any other (test report or type approval).

And it holds for both families that reaction to fire is a separate file: none of these standards covers flammability, which in Italy runs through Class 1 IM type approval (when Class 1 IM is required), and none covers abrasion of the covering, which is measured on its own (how many rubs a hotel needs).

The lines to put in the order

  • the desk chair on a line of its own, separate from the other seating, with its own standard: UNI EN 1335-1:2022 and UNI EN 1335-2:2018;
  • the rest of the seating against UNI EN 16139:2025, and rows fixed to the floor, if there are any, against UNI EN 12727:2017;
  • which model the report was issued on: drawing, date, laboratory and the clauses of the standard applied;
  • castors, gas lift and tilt mechanism named one by one, with the document that covers each;
  • the reaction-to-fire file asked for separately (which documents to ask for);
  • who supplies the specimen to be tested, and when, if the chair is drawn for that project (what a mock-up room is for).

How we work

We design and manufacture in house, with wood, marble, metal and upholstery worked in our own plant. On a hotel supply that changes one concrete thing: the desk chair is handled as the piece it is, with its own line and its own documents, instead of being folded into the schedule of the other seating and discovered at handover. In a hotel project the most valuable thing is time: pieces made to standard, certified and delivered on programme mean a fast opening, and a client who starts invoicing.

The work is in the collections, contract supply in the contract division.

Frequently asked questions

Can a swivel chair on castors have a report against UNI EN 16139?

That standard states that it does not apply to office work chairs, so a report issued against it does not describe a swivel work chair. The question to put to the supplier is against which standard, which edition and which clauses the document accompanying that piece was issued.

Does the bedroom desk chair need Class 1 IM?

That is a different question with a different answer: reaction to fire has nothing to do with the mechanical tests. It depends on the activity and on the applicable fire rules, not on the strength and durability standard, and it is asked for as a separate file.

If a specification says “UNI EN 1335-3”, what arrives?

Nothing issuable against that part: it was withdrawn on 6 December 2018 and its test methods now sit inside UNI EN 1335-2:2018. Better to cite Part 1 and Part 2 in the editions in force, or to require conformity to the edition current at the date of supply.

Talk to us The contract division All guides

The standards cited and their status are verified in the official UNI catalogue at the date of this page, and the passages in quotation marks come from the catalogue summaries; they remain general guidance, and the requirement that applies is the one in the specification and in the approved design.